The
Franklin-Thomas Co., Inc.
25 kW StarPower Generators
We provide actual, scientifically valid data regarding our generators.
An important point - If you look at the graphs from other generator
manufacturers, the curves are smooth.
That is a dead giveaway that the
graph was not created by actual testing,
but is just a mathematical
estimate (hoped for performance).
We also tell you what load we used
(17 ohms) - another important aspect.
We prove our power with actual
testing using equipment with calibration traceable to NIST.
This is real
data and you can tell it is. (5 kW Data Shown)
RPM |
Ft/Lbs |
Pwr In |
Volts |
Amps |
Pwr Out |
Eff% |
258 |
4.461 |
163.3929 |
49.3 |
2.82 |
139.03 |
85.09% |
466 |
7.31 |
483.598 |
86.6 |
4.97 |
430.40 |
89.00% |
540 |
8.4 |
643.9531 |
99.9 |
5.75 |
574.43 |
89.20% |
595 |
8.972 |
757.8573 |
109.1 |
6.28 |
685.15 |
90.41% |
707 |
10.306 |
1034.405 |
127.8 |
7.37 |
941.89 |
91.06% |
835 |
11.87 |
1407.079 |
148.5 |
8.6 |
1277.10 |
90.76% |
908 |
12.51 |
1612.591 |
160.1 |
9.26 |
1482.53 |
91.93% |
1139 |
14.7 |
2376.962 |
195.2 |
11.34 |
2213.57 |
93.13% |
1160 |
14.9 |
2453.722 |
198 |
11.55 |
2286.90 |
93.20% |
1196 |
15.1 |
2563.83 |
202.3 |
11.91 |
2409.39 |
93.98% |
1220 |
15.4 |
2667.238 |
207.9 |
12.15 |
2525.99 |
94.70% |
1235 |
15.4 |
2700.032 |
206.8 |
12.1 |
2502.28 |
92.68% |
1343 |
16.2 |
3088.675 |
221.9 |
13.02 |
2889.14 |
93.54% |
1386 |
16.4 |
3226.92 |
227.4 |
13.33 |
3031.24 |
93.94% |
1390 |
16.69 |
3293.459 |
231 |
13.52 |
3123.12 |
94.83% |
1461 |
17.02 |
3530.132 |
238.7 |
14.04 |
3351.35 |
94.94% |
1501 |
17.4 |
3707.756 |
245.1 |
14.41 |
3531.89 |
95.26% |
|
 |